Flagship Battery-Buffered System Patent Pending · USPTO + CIPO Sister company of XEYAR Ltd.

Battery buffered EV chargers.
Up to 720 kW per cluster from your existing supply.

Battery buffered EV chargers built on the patent-pending XEYAR shared DC-bus architecture. Add high-power EV charging to your existing supply, typically with no transformer upgrade and no long DISCO wait (your site survey confirms it). VPP-ready hardware ships today; grid-service programs are planned for 2027.

eMÖTEN Power load management 10-year battery warranty Delivered and installed across Pakistan
XEYAR Shared DC-Bus Architecture

How a battery buffered EV charger works: grid plus battery, not grid versus battery.

The patent-pending XEYAR design uses a shared DC bus where grid input and battery discharge are simultaneous and additive, not sequential. That single architectural choice is why a modest supply can drive up to 720 kW of EV charging per cluster, typically without a transformer upgrade.

1
Input · Steady Trickle

Grid → DC Bus

A standard three-phase supply feeds the bidirectional PCS, which converts AC to DC for the shared bus. Sized to your sanctioned load (400 V three-phase), flat, continuous, never spiked.

Same PCS regardless of battery chemistry.

2
Buffer · DRACO ESS

DRACO Hub on the Bus

DRACO sits on the DC bus and absorbs / releases on demand. Three storage tiers: Na-ion 5C (symmetric, 20K cycles, cost-optimized), SuperCap 3C (symmetric, 500K+ cycles, ultra-long life), and a 1C/2C outdoor cabinet for clusters above 150 kWh. Selected per installation.

Why 5C? Above 5C, the grid input limits the charge side, so higher C-rates buy nothing. 5C is the engineered ceiling.

3
Output · Additive Power

DC Bus → Chargers

Charger power = grid + battery simultaneously. eMÖTEN CMS is designed to hold at least 50% of nameplate per active port, with eMÖTEN Power, the dynamic load management layer in eMÖTEN CMS. The battery itself is run by its own battery management system (BMS).

OCPP 1.6, 2.0.1 ready.

Patent Pending · USPTO + CIPO

Modular Battery-Buffered Clustered EV Charging System

The shared DC-bus architecture, energy management algorithms, multi-port distribution logic, and battery sizing methodology are covered by the XEYAR patent application (Patent Pending, USPTO + CIPO). Engineered with our sister company XEYAR Ltd. under common ownership. Inventor: Sal Möten · XEYAR Ltd.

USAUSPTO CanadaCIPO

Typically no transformer upgrade

Designed to run on your existing supply, so most sites skip the major DISCO upgrade and the long construction queue. Your site survey confirms it.

VPP-ready hardware today

Bidirectional PCS and DRACO ESS are designed for grid export. Grid-service programs are planned for 2027, with no hardware swap required.

At least 50% per active port

eMÖTEN Power is designed to hold at least half of nameplate power on every active port.

Three storage tiers

DRACO supports Na-ion 5C (cost-optimized), SuperCap 3C (ultra-long life), and a 1C/2C outdoor cabinet for large-capacity sites.

Up to 720 kW total

Full-power L2 or DC Fast on a service that traditionally couldn’t support it. KOMODO 720 hub configuration.

Lower thermal-runaway risk

XEYAR battery storage is UL 9540A tested. Na-ion and SuperCap storage carry far lower thermal-runaway risk than lithium-ion, which simplifies siting in basements and residential towers.

−40°C to +65°C battery storage

The XEYAR storage is rated from mountain winters to desert summers, with no HVAC required. Built for Pakistan's heat.

Delivered across Pakistan

Delivery and installation by MÖTEN Install, quoted with your system.

Two Buffered Cluster Lines

Battery buffered Level 2 and DC fast charging. Two power classes.

Buffered Level 2 for apartment towers, offices and fleet depots. Buffered DC Fast for fuel stations, motorways and fleet hubs. Both built on the XEYAR shared DC bus.

For Apartments · Offices · Depots

Buffered L2 Cluster

11 kW LYNX and PHOENIX chargers clustered with a DRACO ESS hub on a shared DC bus. 8 to 20 ports per cluster, all running off a standard three-phase supply.

8–20ports
Per Cluster
11kW
Per Port
100A
Grid Supply
Charger Families Available
LYNX 11 kW · Free to use · IP65 Premium
PHOENIX 11 kW · Paid · IP65 Premium
Example SKU: LYNX11-B50N-12C = LYNX 11 kW · 50 kWh Na-ion · 12-port cluster
For Highway · Fleet Hub · Public DCFC

Buffered DC Cluster

Full-power DC fast charging, 30 kW to 720 kW per cluster, on a standard three-phase supply. PEGASUS, FALCÃO, SPHINX, KOMODO and MAVERICK families, all clustered on the XEYAR shared DC bus.

2–4dispensers
Per Cluster
720kW
Per Cluster Max
100A
Grid Supply
Charger Families Available
PEGASUS 30 / 40 kW · Workplace & small commercial Entry
FALCÃO 120–360 kW · Workhorse DCFC Workhorse
SPHINX 240 / 360 kW · Ultra-fast urban Ultra-fast
KOMODO 240–720 kW · 4-dispenser HPC hub Hub
MAVERICK Custom engineered · 30 kW to 1 MW+ Custom
Example SKU: SPH240-B150N-2C = SPHINX 240 kW · 150 kWh Na-ion · 2-port cluster
All Cluster Configurations

Battery buffered cluster models. Sized to your site.

Filter by family type. Battery sizes shown are our defaults per port count; every cluster is custom-sized to your site’s load profile, port count and operating environment. All clusters are quoted per site.

Indicative starting prices in Pakistan: Level 2 clusters from PKR 8,736,000, DC clusters from PKR 15,876,000, XEYAR 240 from PKR 33,628,000. Request a quote.

L2 · 11 kW LYNX11-B20N-8C
Entry · Apartments / Offices

LYNX 11 · 8-Port Cluster

Ports × Power8 × 11kW
Battery20kWh Na or SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
L2 · 11 kW LYNX11-B50N-12C
Popular · IP65

LYNX 11 · 12-Port Cluster

Ports × Power12 × 11kW
Battery50kWh Na or SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
L2 · 11 kW PHOENIX11-B50N-16C
Paid · QR card and Raast

PHOENIX 11 · 16-Port Cluster

Ports × Power16 × 11kW
Battery50kWh Na or SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
L2 · 11 kW PHOENIX11-B60N-20C
Paid · IP65

PHOENIX 11 · 20-Port Cluster

Ports × Power20 × 11kW
Battery60kWh Na or SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 30kW PEG30-B20N-2C
Entry DCFC · Workplace

PEGASUS 30 · 2-Port Cluster

Ports × Power2 × 30kW
Battery20kWh Na / 30 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 120kW FAL120-B80N-2C
Workhorse · Highway

FALCÃO 120 · 2-Port Cluster

Ports × Power2 × 120kW
Battery80kWh Na / 100 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 240kW FAL240-B150N-2C
Motorway · Fuel station

FALCÃO 240 · 2-Port Cluster

Ports × Power2 × 240kW
Battery150kWh Na / 200 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 360kW FAL360-B225N-2C
Premium DCFC · Fleet

FALCÃO 360 · 2-Port Cluster

Ports × Power2 × 360kW
Battery225kWh Na / 300 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 240kW SPH240-B150N-2C
Ultra-fast · Premium urban

SPHINX 240 · 2-Port Cluster

Ports × Power2 × 240kW
Battery150kWh Na / 200 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 240kW KOM240-B80N-4D
4-dispenser HPC hub

KOMODO 240 · 4 Dispensers

4 dispensers240kW total
Battery80kWh Na / 100 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 480kW KOM480-B150N-4D
Fleet depot · Logistics

KOMODO 480 · 4 Dispensers

4 dispensers480kW total
Battery150kWh Na / 200 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027
DC · 720kW KOM720-B225N-4D
High-power hub · Buses and trucks

KOMODO 720 · 4 Dispensers

4 dispensers720kW total
Battery225kWh Na / 300 SC
Grid100A · 3-phase
VPP-ready Grid-service programs planned 2027

12 featured configurations shown. Need a different power tier or port count? Talk to engineering →

Grid services (VPP)

VPP-ready hardware. Grid-service programs are planned for 2027.

Every battery buffered EV charger cluster ships with a bidirectional power conversion system and DRACO ESS designed for grid export. Grid-service (virtual power plant) programs are not available yet. They are planned for 2027, and the hardware you install today will not need a swap to join them.

Today

A buffered charger

The battery covers charging peaks, so high-power charging runs on the service you already have, typically with no transformer upgrade.

Built in

Ready for export

Bidirectional power conversion and battery storage designed for grid export, with eMÖTEN Power managing the chargers and the battery run by its own BMS.

Planned 2027

Grid-service programs

When programs launch, eligibility and any payments will depend on your DISCO, the program rules and how the battery is used.

We do not quote VPP revenue today. Your quote covers charging hardware, storage, installation and eMÖTEN plans, sized for your site.

Get a battery-buffered quote
Buffered vs Non-Buffered

Battery buffered vs conventional EV charging. Same site, different architecture.

Reference 12-port LYNX 11 kW office deployment. What each path requires, in time, infrastructure and recurring cost.

Engineering comparison. Architecture and feasibility, not project pricing. For project-specific quotes including your tariff, delivery and installation, request a site assessment →
Scenario: 12 × LYNX 11 kW ports · Existing service: small three-phase supply
Metric Conventional Non-Buffered XEYAR LYNX11-B50N-12C Winner
Required Service About 132 kW upgrade Existing existing
DISCO Upgrade Required · transformer build Typically none
Time to Install Several months (DISCO queue) 60–90 days lead time
Basement / Tower Siting Lithium storage rules & suppression Lower thermal-runaway risk
Operating Range Varies by chemistry −40 °C to +65 °C
Delivery Charged separately Quoted with the system
Grid services (VPP) Not possible VPP-ready · programs planned 2027
Software Vendor subscription per port eMÖTEN plans per port
Architecture Verdict DISCO-dependent · high recurring cost Grid-light · VPP-ready · lower OPEX
10yr
Battery warranty · 2 yr hardware
TYPE 2
and CCS2 connectors
97%
Uptime SLA on eMÖTEN
−40° / +65°C
Battery operating range · No HVAC
Certified · Compliant
TÜV Rheinland (DC) IEC 61851-1 IEC 61851-23 / -24 Type 2 (IEC 62196-2) CCS2 OCPP 1.6, 2.0.1 ready IEC 61851 IP54 DC · IP65 L2 Patent Pending · USPTO + CIPO UL 9540 (battery) UL 9540A (battery) UL 810A (battery) IEC 62619 (battery) BMS-managed storage

XEYAR battery storage certified to UL 9540, UL 9540A, UL 810A and IEC 62619. MÖTEN DC fast chargers TÜV Rheinland certified to IEC 61851.

Ready for buffered?

EV charging without a transformer upgrade. Keep your existing supply.

Frequently Asked

Battery buffered EV charger questions. Straight answers.

Battery buffered EV charger architecture, inspection, VPP roadmap, warranty, freight and deployment time: the answers engineers and procurement managers ask first.

What is a battery buffered EV charger, and how is it different from a regular DC fast charger?

A battery buffered EV charger has on-site energy storage between the grid and the chargers. It stores energy from a modest supply and releases it when EVs charge, so you get high charging power on a small grid connection. A regular 240 kW DC fast charger needs a 240 kW supply; a buffered SPHINX 240 cluster delivers 240 kW per port while the buffer has charge, and the grid recharges it between sessions.

Do I really not need a transformer upgrade?

In most cases, no. Buffered clusters are designed to run on your existing three-phase supply; the DRACO ESS covers the difference between grid input and charger demand. That typically avoids a major transformer upgrade and the long wait for your DISCO. A site survey confirms your sanctioned load and tariff.

Sodium-ion or supercapacitor: which should I choose?

Both sit on the same shared DC bus. Sodium-ion (5C, about 20,000 cycles) is the cost-optimised choice for most sites. Supercapacitor (3C, 500,000+ cycles) suits sites with many short, high-power sessions. Clusters above 150 kWh use a 1C/2C outdoor cabinet. Our engineers select the chemistry for each site.

Is it safe in basements and residential towers?

XEYAR battery storage is UL 9540A tested, and sodium-ion and supercapacitor storage carry far lower thermal-runaway risk than lithium-ion. Local fire and building rules still apply site by site, and we provide the documents your engineer and building management need.

How much does it cost in Pakistan?

Every cluster is quoted per site. Indicative starting prices: Level 2 clusters from PKR 8,736,000, DC fast clusters from PKR 15,876,000, and XEYAR 240 from PKR 33,628,000. Request a quote for your site.

How long from order to commissioning?

Battery buffered clusters are built to order; lead time is typically 60 to 90 days from order, depending on configuration. The big saving is not waiting for a bigger DISCO connection.

What warranty covers a battery buffered cluster?

The charger hardware carries a 2-year manufacturer warranty, extendable to 5 years, and the battery carries a 10-year warranty from the manufacturer. The eMÖTEN platform carries a 97% uptime SLA.

Can it provide grid services (VPP)?

The hardware is VPP-ready: the bidirectional power conversion system and DRACO ESS are built for grid export. Grid-service programs are planned for 2027 and are not available yet, so today the system works as a buffered charger. We do not quote VPP revenue.